msdsDimplerarrow12Dimpler – Model D 500i

The Model D500i Dimpler has become an indispensable tool for TEM specimen preparation. The dimpling technique, which is applicable to a myriad of material types, yields a higher quality specimen with a broader, near electron transparent area which reduces ion milling times. The Model D500i automates the dimpling technique so that the most demanding specimen can be dimpled to < 10 microns routinely and repeatedly. Real time measurement of tool height, specimen thickness, and tool run out allow the user to precisely control the dimpling process. With the proper tooling and parameter adjustment, the dimpling technique with the D500i can be completed with ease.

Description

The Model D500i is a precision electro-mechanical metallographic lapping instrument. It will continuously monitor and control dimpling parameters and accurately terminate at a preset specimen thickness. This breakthrough in electronic and mechanical integration has added repeatability and reliability to the dimpling process, as well as automation.

Functions

Several operating functions of the Model D500i are built in to facilitate repeatable, usuable dimpled samples.

Z Position

The Z position display indicates the termination set point and the dimple depth from the Non-Contact Sensor and is both analog and digital. The analog elliptical bar displays the Z Position of the arm in real time so tool run out and damping effects can be monitored. The digital LED display in microns is updated once every tool revolution by the Tool Phase Detector at the same angular site. This negates any error due to tool run out, especially significant when using padded tools.

Termination

Four factors improve the termination accuracy:

  1. Non-Contact Position Sensor
  2. Tool Phase Sensor
  3. No external measuring device
  4. Magnetically coupled arm damping

The Non-Contact Position Sensor measures the location of the fulcrum arm which corresponds precisely to the thickness of the specimen.This sensor has an accuracy of better than one micron. Since it is non-contacting there are no detrimental effects on the action of the fulcrum arm. The reaction time of the sensor is fast enough to terminate the dimpling process the first time the Tool Phase Sensor indicates that the Z termination set point has been reached. Specimen thickness is measured directly on the D500i with the tool surface as the measuring point. The dimple depth and the Z termination set point are measured with the same reference. This prevents any measurement error from being translated directly to a termination error.

Damping

Damping of the arm is accomplished by using position information from the Non-Contact Position Sensor, processing it and feeding it back to the arm motor, which controls the up/ down force of the arm. The position snesor and the processing circuit is fast enough to actively dampen any vibration the arm may experience. Since the damping force is magnetically coupled to the arm there is no mechanical play in the system, allowing damping response on the sub-micrometer level. Damping is adjustable from zero damping to stiff damping.

Damping offers three significant attributes

  1. Vibrations that can crack thin specimens are greatly reduced.
  2. Keeps tools round, negating escess impacts, providing more accurate Z position control.
  3. Tool gently contact the specimen when the arm is lowered.

Automated Controls

Automated features make the dimpling process more repeatable and easy to use. Tools are raised and lowered at the touch of a button; dimpling force, damping force, fine balance, and Z offset (termination point) all are set from the front panel.

Once dimpling has begun no monitoring is necessary. After the initial specimen thickness has been measured, the specimen is mounted an dthe user simply selects a dimple depth and begins dimpling.The precise Z position of the tool/surface interface is continuously displayed while dimpling with any tool. When the selected dimple depth is reached the D500i controls will automatically raise the arm then stop the tool rotation, specimen rotation, and clock timer.

Specimen Mounting

Specimens are mounted on optically smooth sapphire flats. Low thermal mass of the flat reduces mounting and dismounting times and the smooth surface allows the dimpled specimens to be gently slipped off. The hardness of sapphire limits damage if specimens are accidentally dimpled through due to operator error. The retainer ring which secures the sapphire flat also serves as a slurry reservoir. A specimen mounting jig is used for specimen centering during mounting. For off center dimples a special Eccentric Platen with a centering microscope is available.

Tools*

Tools 1i and 2i are flatting tools and Tools 3i and 4i are dimpling tools. Tools 2i and 4i are supplied pre-padded with various types of metallographic polishing pad. In addition to saving the user the time of padding tools the machine formed padded tools have TIR (Total Indicator Reading) approaching Tools 1i and 3i. Dimpling tool geometries have been improved, so that Dimpling Tools 3i and 4i will produce 380 micron diameter dimpled areas.

Working Interface

Research has indicated that Tools 2i and 4i have a working diameter within the nap of the pad. Whereas the DZ (change in Z offset value) between the specimen and the hard tool surface is virtually zero, the DZ between the"working interface" and the specimen is a function of dimpling force, tool speed, damping force, and pad compliance. After the dimpling force, tool speed, and damping force are selected, the working diameter will stabilize at the working interface of the pad. This working interface is monitored on the Z display and used as a reference location from which a specimen is to be dimpled further. A user can control the dimple depth and removal with a virtually seamless padded tool. This position control allows the dimpling force to approach zero within 1 gram increments.

Example of a silicon based integrated circuit device prepared using the Model D500i Dimpler. The image shows the excellent uniformity obtainable using the dimpling technique.

Specifications

Tolerances
Z Offset: Accuracy: 1 micron
  Range: 2000 microns
Z Termination Accuracy: Tools 1i/3i: < +/- 1 micron
  Tools 2i/4i: < +/- 2 microns
Tool Force: Range: 1 - 200 grams
    1 gram steps
Balance: Sensitivity: 1 gram
  Range: 50 grams
Tool Speed:   100 - 600 RPM
Specimen Platen Speed:   10 RPM
Tool Shaft:   0.5 micron TIR
Tools: Tools 1i/2i: +/- 1 micron TIR
  Tools 3i/4i: +/- 2 micron TIR
Platen Surface:   < 0.5 micron TIR
Dimensions: Length: 68.6 cm
  Width: 35.6 cm
  Height: 33 cm
  Weight: 32 kg
Electrical:   120 VAC / 60 Hz
  240 VAC / 60 Hz

Ordering

50170-500i

Dimpler – Model D500i
Includes:

  • Tool Retaining Screw
  • Allen wrench set, 1/16 through 3/16
  • DVD for Installation and Setup
*Tool Sets sold separately - requires at least one tool set to operate

each 22,000.00 Add to Cart
msdsmsds*Tool Sets - Requires at least one tool set to operate
50170-41 Standard Tool Set for Dimpling 3mm TEM Samples
Includes one of each of the following:
  • Dimpling Tool 1i Flatting (50170-08)
  • Dimpling Tool 2iM Flat Polishing (Soft Pad) (50170-09)
  • Dimpling Tool 2iT Flat Polishing (Hard Pad) (50170-10)
  • Dimpling Tool 3i Dimpling (Stainless Steel)(50170-11)
  • Dimpling Tool 4iM Flat Polishing (Soft Pad)(50170-12)
  • Dimpling Tool 4iT Flat Polishing (Hard Pad)(50170-13)
each 410.00 Add to Cart
50172-01 Standard Platen Set to be used with Standard Tool Set
Includes:
  • Platen, Adjustable (transferable to Model 150 Polisher)(50170-22)
  • Base, Magnetic, Standard (50172-04)
  • Slurry Retaining Ring (50172-07)
each 535.00 Add to Cart
50170-42 Large Area Tool Set for Creating Larger Flat Area and/or Polishing 3mm or Larger Samples
Includes:
  • Dimpling Tool, Large Area, 1" Dia x 0.125" Thick (50173-01)
  • Dimpling Tool, Large Area, 1" Dia x 0.250" Thick (50173-03)
  • Dimpling Tool, Large Area, 1" Dia x 0.500" Thick (Counterbored to maintain tool center alignment)(50173-05)
  • Dimpling Tool, Large Area, 1" Dia x 0.250" Thick (Counterbored to maintain tool center alignment)(50173-07)
  • Dimpling Tool, Large Area, 1" Dia x 0.125" Thick, Polishing - Soft Pad(50173-02)
each 465.00 Add to Cart
50172-02 Large Area Platen Set to be used with Large Area Tool Set
Includes:
  • Platen, Large Area, 1" Diameter x 0.35" Thick - for use with 1" diameter Tools
  • Base, Magnetic, Large Area, 0.281" Height (50172-06)
each 310.00 Add to Cart
Standard Dimpling and Dimple Polishing Tools- To Replace or Add-On to a Tool Set
50170-06 Sapphire Flat (x2) size ¾" Dia x 0.53mm each 79.00 Add to Cart
50172-07 Slurry Retaining Ring each 110.00 Add to Cart
50170-08 Tool 1i Flat each 64.00 Add to Cart
50173-01 Tool 1i Flat (Large Area, 1") each 75.00 Add to Cart
50170-09 Tool 2iM Flat Polishing each 95.00 Add to Cart
50170-10 Tool 2iT Flat Polishing each 95.00 Add to Cart
50170-11 Tool 3i Dimpling each 95.00 Add to Cart
50170-12 Tool 4iM Dimple Polishing each 95.00 Add to Cart
50170-13 Tool 4iT Dimple Polishing each 95.00 Add to Cart
50173-08 Tool 3i Dimpling Copper each 159.00 Add to Cart
50173-09 Tool 1iD - 15µm Diamond Flatting each 295.00 Add to Cart
50173-10 Tool 1iD - 9µm Diamond Flatting each 295.00 Add to Cart
50173-11 Tool 1iD - 6µm Diamond Flatting each 295.00 Add to Cart
50173-12 Tool 1iD - 3µm Diamond Flatting each 295.00 Add to Cart
50173-13 Tool 3iD - 3µm Diamond Dimpling each 295.00 Add to Cart
50173-14 Tool 3iD - 1µm Diamond Dimpling each 295.00 Add to Cart
50173-15 Tool 3iD – 0.25µm Diamond Dimpling each 295.00 Add to Cart
Large Area Dimpling & Dimple Polishing Tools- To Replace or Add-On to a Tool Set
50173-01 Dimpling Tool, Large Area, 1" Dia. x 0.125" Th. each 75.00 Add to Cart
50173-02 Dimpling Tool, Large Area, 1" Dia. x 0.25" Th., Polishing - Soft Pad each 95.00 Add to Cart
50173-03 Dimpling Tool, Large Area, 1" Dia. x 0.250" Th. each 75.00 Add to Cart
50173-04 Dimpling Tool, Large Area, 1" Dia. x 0.250" Th., Polishing - Soft Pad each 95.00 Add to Cart
50173-05 Dimpling Tool, Large Area, 1" Dia. x 0.500" Th. (Counterbored to maintain tool center alignment) each 125.00 Add to Cart
50173-06 Dimpling Tool, Large Area, 1" Dia. x 0.500" Th., Polishing - Soft Pad (Counterbored to maintain tool center alignment) each 145.00 Add to Cart
50173-07 Dimpling Tool, Large Area, 1" Dia. x 0.250" Th. (Counterbored to maintain tool center alignment) each 95.00 Add to Cart
50173-16 Dimpling Tool, Large Area, 1" Dia. x 0.250" Th., Polishing - Soft Pad (Counterbored to maintain tool center alignment) each 115.00 Add to Cart
50173-17 Dimpling Tool, Large Area, 1" Dia. x 0.125" Th., Radiused Edge each 95.00 Add to Cart
50173-18 Dimpling Tool, Large Area, 1" Dia. x 0.156" (4mm) Th. (Counterbored on one side to maintain tool center alignment to be used with... each 95.00 Add to Cart
Accessories
50172-08 MicroSaw – includes diamond cutting wheel and support collar assembly each 325.00 Add to Cart
50170-40 Alignment Microscope each 1,795.00 Add to Cart
50170-50 Specimen Vice (for X-sectional prep, includes "PTFE" jaws) each 747.00 Add to Cart
50150-50 Model 150 Lapping Fixture each 2600.00 Add to Cart
50170-22 D500i Holder, bottom platen, transferable to Model 141 (Need to have MEP)* each 140.00 Add to Cart
50170-17 Shim Control Lapping Fixture each 747.00 Add to Cart
50170-18 Shim Control Lapping Fixture (can be replaced by option 1 or 2*) each 902.00 Add to Cart
50170-04 MEP Centering Stand (for use w/magnetic base) each 230.00 Add to Cart
50170-19 Additional Knob Thumb Screw each 20.00 Add to Cart
50170-20 Additional Allen Wrench Set (1/16 – 3/16) each 22.00 Add to Cart
72000 Double Edge Coated Razor Blade bx 39.50 Add to Cart
Fixed and Magnetic Bases
50172-05 Fixed Base for Large Area Tools each 230.00 Add to Cart
50172-03 Fixed Base (for standard tools) each 230.00 Add to Cart
50172-06 Magnetic Base for Large Area Tools, 0.281" each 230.00 Add to Cart
50172-04 Magnetic Base (for standard tool) each 230.00 Add to Cart
50170-21 Magnetic Base (special, 0.611 height) each 230.00 Add to Cart
50170-03 Magnetic Base for Large Area Tools, 0.245" each 230.00 Add to Cart
Consumables
50170-14 3µm Diamond Polycrystalline Suspension, 2 oz. each 120.00 Add to Cart
50170-15 1µm Diamond Polycrystalline Paste, 2 oz. each 120.00 Add to Cart
50170-56 .25um Diamond Polycrystalline Paste each 45.00 Add to Cart
50170-57 .25um Diamond Polycrystalline Suspension each 95.00 Add to Cart
50170-16 Lapping Vehicle, 4 oz each 16.00 Add to Cart
50419-20 Mounting Wax, QuickStick135 each 73.00 Add to Cart

Tripod Polishers for SEM TEM Preparation arrow12arrow12

Check out our Newest and Most Revolutionary Products...

DuraSiN™ Film and MeshDuraSiN™ Film and Mesh products are affordably-priced, durable, nonorganic, low scatter support grids for quantitative TEM and X-ray analysis. Unlike other support films and grids, DuraSiN™ Film and Mesh products can withstand harsh chemical and temperature environments. Introducing DuraSIN™, revolutioning the way samples are prepared and analyzed in the transmission electron microscope. SEM image of a DuraSiN™ Film (taken from the back side) SEM image of a DuraSiN™ Mesh (taken from the back side). For more information, click here.